Good Quality Biogas Room Heater
Biogas romm heater
Suitable gas: Biogas
Gas consumption rate: 0.3m3/h
Gross weight: 21kgs/20SETS
Outside dimension: 590×590×410mm
a heater could keep warmth for a room about six to nine square meters,
1, In winter, when switched to “winter”, all burners of WSCT will open to enhance fire.
2, In summer, when switched to “summer”, half burners of WSCT will open to weaken fire for saving energy.
flue jointer
Shell
Winter and summer conversion switch
Gas Knob
Water Knob
Battery Box
Gas Inlet Jointer
Heat exchanger
Ignition needle
Pulse igniter
sluice valve electromagnetic valve
gas valve
water inlet
Drainage valve
coupled valve
micro switch
hot water outlet
Dimension
Model | a | b | c | d | e | f | |
6L | 290 | 80 | 165 | 430 | 120 | 470 | |
7L | 305 | 80 | 170 | 500 | 150 | 540 | |
8L | 320 | 110 | 175 | 520 | 175 | 550 | |
9L | 340 | 110 | 250 | 600 | 180 | 650 | |
10L | 335 | 120 | 250 | 600 | 170 | 630 | |
12L | 365 | 110 | 240 | 600 | 185 | 700 |
(Notice: the picture of user’s manual might be little bit different from product. We keep improving the appearance of products. If updated, you will not be noticed. Thanks.)
Technique Parameter
Product Name | Domestic biogas water heaters | |||||||||||
Model | JSD12- | JSD13- | JSD14- | JSD16- | JSD18- | JSD20- | JSD24- | |||||
Heat flux | 12KW | 13KW | 14KW | 16KW | 18KW | 20KW | 24KW | |||||
Hot water production rate ( at 25°C) | 6L/min | 6.5/min | 7L/min | 8L/min | 9L/min | 10L/min | 12L/min | |||||
Rated gas pressure | PLG | Natural Gas | Artifical coal gas | Biogas | ||||||||
2800pa | 2000pa | 1000pa | 1600pa | |||||||||
Ignition | Automatic ignition by electric pulse | |||||||||||
Exhaust | Natural exhaust flue | |||||||||||
flue diameter | JSD12·JSD13·JSD14 | JSD16·JSD18 | JSD20 | JSD24 | ||||||||
90 | 100 | 110 | 120 | |||||||||
Water pressure | 0.025—0.8 MPS | |||||||||||
Connection pipe | Gas pipe | Diameter 9.5mm (Inner diameter) Diameter9.5 mm | ||||||||||
Cold water pipe | fitted short pipe or G1/2″steel pipe | |||||||||||
Hot water pipe | fitted long pip orG1/2 steel pipe |